Guangzhou Rongtao Medical Tech LTD.

To be the top preferred ultrasound service company worldwide!

Manufacturer from China
Verified Supplier
4 Years
Home / Products / Ultrasonic Board /

10039639 Ultrasound Machine Components S2000 VI Board

10039639 Ultrasound Machine Components S2000 VI Board

Ask Latest Price
Brand Name :Siemens
Model Number :10039639
Price :Negotiable
Payment Terms :T/T,Western Union
Delivery Time :2-4 work days
Packaging Details :Neutral Package
Category :components of ultrasound machine
Description :patient data module
Service :Outright sale, exchange sale
Warranty :60 days/ 90 days
Condition :Original Siemens
Purpose :Diagnostic imaging
Contact Now

Add to Cart

Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
View Product Description

Siemens S2000 VI Board (P/N:10039639)

1. P/N:10039639

2. original one in excellent working condition

3. with 60 days warranty

Outright/exchange/repair is available for ultrasound parts/Assy.

10039639 Ultrasound Machine Components S2000 VI Board

Other ultrasound parts that we can offer:

Repair List of Featured Ultrasonic Board & Assy
Brand System Description Part Number
GE Logiq P5 APS Power Supply 5140505/5166108/5329667
GE Logiq P5 CPU mainboard 5168431
GE Logiq P5 SYSCONPM 5177848-3
GE Logiq P6 CPU mainboard
GE Logiq P6 PST Power Supply 5245004/5244555
GE Logiq P6 SYSCONML 5252326-3
GE Logiq S7/Logiq S8 CPS Power supply 6626600 R02/5413249-3
GE Logiq S7 BF128 transmitting board 5392446
GE Logiq S7 GFS board 5371196
GE Logiq S8 BF192 Beamformer 5357234-2
GE Logiq S8 GFS board 5371196-2/5455247
GE Logiq E9/vivid E9 GTX GA200726
GE Logiq E9 MRX Board 5393908/5393912
GE Logiq E9/vivid E9 GFI2 5161631
GE Logiq E9 BEP Power Supply 5393800-3/5166790-2
GE Voluson E6/Voluson E8 RSR KTI301394-2/KTI196357
GE Voluson E6/Voluson E8 RST KTI301148
GE Voluson E6/E8/E10 RSX KTZ303054 /KTI303054
GE Voluson E6/E8/E10 RFM201 FE mainboard KTZ303916
GE Voluson E6/E8/E10 RFM221 FE mainboard KTZ303915
GE Voluson E6/Voluson E8 RFI/ RFI21b Board KTI300614/KTI302197-6
GE Voluson S6/S8/P8 BF64 5396937-2
GE Voluson S6/S8/P8 BF128 5338209-2
GE Voluson S6/S8/P8 CPS Power supply 5393431
GE Voluson S6/S8/P8 RFS board 5364098-2/5364098-3
GE Voluson S6/S10/P8 BF192 board 5357234
Aloka Alpha 5 mainboard EP493700DD
Aloka Alpha 6 RX Beam Former EP555501AA
Aloka Alpha 6 CW board EP555700
Aloka Alpha 6 CPU mainboard EP537000/EP563000
Aloka Alpha 6 TX/RX EP555300
Aloka Alpha 6/Alpha 7 DOM EP550000AA
Aloka Alpha 7 RX Beam Former EP539100BB/EP539500DG/EP539501DG
Aloka Alpha 7 CPU mainboard EP558900
Aloka Alpha 7 TI Board EP539000
Aloka Alpha 7 TX board EP548300BB
Aloka Alpha 7 touch screen L-Key-93H
Aloka Alpha 10 RX Beamformer board EP531800CE
Aloka Alpha 10 wave generator Board EP495000HH/EP495000HJ/EP495000FF
Aloka Alpha 10 High-voltage Board EP541800
Aloka Alpha 10 CPU mainboard EP496000
Hitachi F31 RX Beamformer board EP568900
Hitachi F31 mainboard EP575700BC/EP560800
Hitachi F37 TX/RS EP557400/EP557300
Hitachi F37 mainboard EP575700BC/EP560800
Hitachi F37 BF Beamformer board EP557400
Hitachi F37 RX mainboard EP557500
Aloka F75 CONT-B EP556700BB
Aloka F75 USP board EP556600
Aloka F75 Cell Board EP558800
Hitachi HI VISION Avius RDBF board 7513907A/7513612
Hitachi HI VISION Avius CONT-B 7513734A
Hitachi HI VISION Avius/Preirus Cell board 7345930A
Hitachi HI VISION Preirus RX Board CZH4AA
Hitachi HI VISION Preirus TX Board 7513629A
Hitachi HI VISION Preirus CONT-B 7513640A/CZ84AJ
Hitachi Arietta 60 TX
Hitachi Arietta 60 RX
Hitachi Arietta 60 CELL EU-9160C
Hitachi Arietta 70 TX EP572300AA
Hitachi Arietta 70 RX EP572900/EP572200
Hitachi Arietta 70 CELL
Hitachi Noblus CELL
Hitachi Noblus CONT-B
Hitachi Ascendus TX
Hitachi Ascendus CELL 7352830A
Siemens X150/G40 BE 10131804
Siemens X300 BE 2.0/BE 3.0/BE 7.5 10131990
Siemens X700 BE 10136465
Siemens X700 RC 10136467
Siemens X700 TI 11014292
Siemens Antares BE 7472421
Siemens Antares CB 7288504
Siemens S1000/S2000 RM200 10038592
Siemens S1000/S2000 RM220 10853882/10439172
Siemens S2000 RM300 10852163
Siemens S2000 high version/S3000 RM301 10854749
iU22/iE33 CB Channel Board 453561156011/453561156012/453561303902
iU22/iE33 AIM Board 453561210241/453561210243/453561210321/453561210243
iU22/iE33 FEC Front End Controller 453561278261/453561278266/453561464291/453561153751
iU22/iE33 EMB excelsior motherboard 453561419431/453561382231/453561419431
iU22/iE33 UMB Unified Motherboard 453561254492/453561360251
HD7/Envisor T/R board 453561448371
HD11/HD11XE SP Board 453561210154/453561343282
HD15 ACB acquisition control board 453561197145/453561197144
HD15 AIM board 453561197306
CX50 control panel 453561685791
CX50 mainboard 453561368033/453561622163/453561495832
CX50 Power Supply board 453561375144/453561384831/453561473243
Affiniti 50 ACQ acquisition control board 4535161610416/4535161610426
Affiniti 70 ACQ acquisition control board
EPIQ 5/EPIQ 7 ACQ Acquisition Module board 453561734844/453561704246
Biosound Mylab Series CPU mainboard 9501361000
Toshiba Aplio 300/400/500 mainboard PM30-38696
Toshiba Aplio 300/400/500 VI
Toshiba Aplio 300/400/500 TX PM30-38691
Toshiba Aplio 500 RX ywm2056*a
Toshiba Xario 200 TX PM30-32732-1
Toshiba Xario 200 RX PM30-32733-1
Remarks
1.The repair cycle is within 3-5 days.
2.Warranty after fixed:60 days.
3. Kindly send us the estimated main faults (better to have image) for our engineer to prejudge.
4.Package price is available if repair 3 pcs or more at one time.
5.Extra discount for VIP partners.
6.You could have different part No.under same description.

Knowledge point

Harmonic imaging

Harmonic imaging exploits non-linear propagation of ultrasound through the body tissues. When the frequency of emitted sound wave is f 0, the frequency of echo (due to reflection or scattering) includes f 0 (called fundamental wave), 2f 0, 3F 0 and so on The second harmonic (2f 0) has the largest energy.

Ultrasonic harmonic imaging (UHI) is based on the information of human body carried by the second harmonic in echo (reflection or scattering). Harmonic imaging without UCA is called native harmonic imaging or tissue harmonic imaging. Harmonic imaging using UCA (ultrasound contrast agent) is called contrast harmonic imaging.

How we support?

Professional & passionate pre-sale service team
10 years experienced repair technician team
Reliable & responsible quality control team
Experienced & specialize after-sale technical support team


We are committed to using our expertise in the industry to identify and provide the right medical equipment to our customers at the best price in a timely and professional manner.

Our Vision -- To be the top preferred third-party service company worldwide!

The front end refers to the ultrasonic image processing unit

1. Probe interface board

2. Transmitting and receiving board

3. Control panel

4. Processing board

5. Video display panel

6. Front and back end connection control panel

Back end refers to the PC background processing unit

1. Mainboard

2. ATX power supply

3. Graphics card

4. Memory

5. Hard disk

6. Front and back end connection board

China 10039639 Ultrasound Machine Components S2000 VI Board for sale

10039639 Ultrasound Machine Components S2000 VI Board