Add to Cart
Toshiba PSU-30BT (5S2) Sector Ultrasound Transducer Probe/Medical Apparatus
Toshiba PSU-30BT (5S2) Sector ultrasound transducer
1.Type:Sector
2.Frequency: 2.0-4.8 MHz
3.Compatible system:Xario 100, Xario 200
4.Application: cardiac
5.Condition: original, in working condition (fully tested)
6.With 60 days warranty
Other Toshiba probes we can offer:
Brand | Model | Compatible System |
Toshiba/Canon | PLF-805ST | SSA-340A&SSA-350A |
Toshiba/Canon | PLM-1204AT | PowerVision 6000 SSA-370A/ Nemio 17 SSA-550A/ Xario SSA-660A |
Toshiba/Canon | PLM-703AT | Powervision 6000 and Nemio |
Toshiba/Canon | PLM-805AT | PowerVision 6000 SSA-370A/ Nemio 17 SSA-550A |
Toshiba/Canon | PLT-1005BT | Aplio 300/ Aplio 400/ Aplio 500 |
Toshiba/Canon | PLT-1204AT | Aplio 50 SSA-700A/ Aplio SSA-750A/ Xario Series |
Toshiba/Canon | PLT-604AT | Xario Series / Aplio 50 SSA-700A/ Aplio SSA-750A |
Toshiba/Canon | PLT-704AT | Aplio 50 SSA-700A/ SSA-750A/ Xario |
Toshiba/Canon | PLT-704SBT | Xario SSA-660A |
Toshiba/Canon | PLT-805AT | SSA-700A/ Aplio SSA-750A/ Aplio SSA-770A/ Xario SSA-660A |
Toshiba/Canon | PLU-1204BT | Xario 100/Xario 200 |
Toshiba/Canon | PSM-25AT | PowerVision 6000 SSA-370A/ Nemio 17 SSA-550A |
Toshiba/Canon | PSM-37CT | PowerVision 6000 SSA-370A/ Nemio 17 SSA-550A |
Toshiba/Canon | PST-25ST | Viamo |
Toshiba/Canon | PST-30BT | Xario & Aplio Series |
Toshiba/Canon | PST-30BT | Aplio 50 SSA-700A/ Aplio SSA-750A/ Artida SSH-880CV/ Xario SSA-660A |
Toshiba/Canon | PSU-25BT(5S1) | Xario 100/ Xario 200 |
Toshiba/Canon | PSU-30BT(5S2) | Xario 100/ Xario 200 |
Toshiba/Canon | PVE-382M | 77B/90A/100A/240A/250A/TOSBEE |
Toshiba/Canon | PVF-375MT | SSH-140A/ SSA-270A/ SSA-340A |
Toshiba/Canon | PVM-375AT | PV 6000 SSA-370A/ Nemio 17 SSA-550A/ Nemio XG SSA-580A/ Nemio 30/ SSA-370A |
Toshiba/Canon | PVM-621VT | PowerVision 6000 SSA-370A/ Nemio 17 SSA-550A |
Toshiba/Canon | PVM-651VT | PowerVision 6000 SSA-370A/ Nemio 17 SSA-550A |
Toshiba/Canon | PVT-375BT | Aplio 50 SSA-700A/ Aplio SSA-750A/ Aplio SSA-770A/ Aplio XG SSA-790A/ Xario SSA-660A/ SSA-680A |
Toshiba/Canon | PVT-375BT | SSA-700A/SSA-750A/ Aplio SSA-770A/SSA-790A/SSA-660A/ SSA-680A |
Toshiba/Canon | PVT-382BT | Aplio XG/Aplio MX/Xario XG/Xario/Viamo (2.0 and above)/Aplio 500/Aplio 300 |
Toshiba/Canon | PVT-575MV | Xario SSA-660A/ Aplio XG |
Toshiba/Canon | PVT-661VT | Aplio 50 SSA-700A/ Aplio SSA-750A/ Xario SSA-660A |
Toshiba/Canon | PVT-661VT | Aplio 50 SSA-700A/ Aplio SSA-750A/ Xario SSA-660A |
Toshiba/Canon | PVT-674BT | Aplio 50 SSA-700A/ Aplio SSA-750A |
Toshiba/Canon | PVT-675MV | Xario 100/ Xario 200/ Aplio MX |
Toshiba/Canon | PVT-681MV | Aplio 300/ Aplio 400/ Aplio 500/ Xario XG |
Toshiba/Canon | PVT-712BT | Aplio series/ Xario series |
Toshiba/Canon | PVU-781VT | Xario |
Knowledge point
Harmonic imaging
Harmonic imaging exploits non-linear propagation of ultrasound through the body tissues. When the frequency of emitted sound wave is f 0, the frequency of echo (due to reflection or scattering) includes f 0 (called fundamental wave), 2f 0, 3F 0 and so on The second harmonic (2f 0) has the largest energy.
Ultrasonic harmonic imaging (UHI) is based on the information of human body carried by the second harmonic in echo (reflection or scattering). Harmonic imaging without UCA is called native harmonic imaging or tissue harmonic imaging. Harmonic imaging using UCA (ultrasound contrast agent) is called contrast harmonic imaging.