Guangzhou Rongtao Medical Tech LTD.

To be the top preferred ultrasound service company worldwide!

Manufacturer from China
Verified Supplier
5 Years
Home / Products / Ultrasound Machine Repair /

GE Voluson P8 Sonography Ultrasound Machine Repair BF128 Transformer

Contact Now
Guangzhou Rongtao Medical Tech LTD.
Visit Website
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:Aurora Zhu
Contact Now

GE Voluson P8 Sonography Ultrasound Machine Repair BF128 Transformer

Ask Latest Price
Video Channel
Brand Name :GE
Model Number :Voluson P8
Price :Negotiable
Payment Terms :T/T,Western Union
Delivery Time :2-4 work days
Packaging Details :Neutral Package
Category :ultrasound treatment machine
Description :colour doppler machine
System :4d colour doppler ultrasound
Warranty :60 days after fixed
Condition :GE Voluson P8 basic medical equipment in hospitals
Purpose :urology ultrasound machine
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

GE Voluson P8 Ultrasound Sonography Machine Repair

GE Voluson P8 System Reports Error

The parts with high failure rate&available in stock of this machine:

1.DBM64

2.DBM128

3.BF64

4.BF128 Transformer

5.CPS Power Supply

6.RFS Mainboard


Common faults of GE ultrasound machine

System Faults Solutions
LOGIQ 500 No image when scanning far field Check power supply, reinsert the circuit board. Suggest to do metal earthing.
LOGIQ 500PRO Artifacts appear in color flow imaging (betweentimes) Replace ACFP3 board
LOGIQ 200E No image on displayer, whereas normal image in workstation Fix displayer
LOGIQ 200E Curved lines interpolated into sector-shaped image, from near field to far field Replace DSC board, and make sure the system earthing
LOGIQ 200 No sound for the probe, requires multiple startup Detect low voltage and external power supply (MST)
LOGIQ BOOK Lithium battery- short life Replace lithium battery, and upgrade the system to 2349040-23 KB824146
LOGIQ BOOK Crash
Reinstall the system
LOGIQ 400MD cardiac probe shows clutter filte, interference in far field Repair cardiac probe S317, then test the voltage
LOGIQ 400MD Noisy in probe, no waves in scan area Connecting board failure, try to connectwith TRDR and HBFR
LOGIQ 400CL Automatic interruption High voltage failure, need repair
LOGIQ 180 Screen wobble Displayer failure, need stabilized voltage supply
LOGIQ 500MD No image after boot (betweentimes) Detect five low voltage value
LOGIQ 200PRO No image Detect the channel board
LOGIQ 9 No scan area, no ultrasound image MSTE and high voltage power supply failure, need repair

Inquiry Cart 0