Aloka UST-979-3.5 Ultrasound Transducer Probe Lens And Connector Replacement
Model: ALOKA UST-979-3.5
Fault Phenomenon: The cable is wrapped with tape, the cable is yellow and damaged, the strain relief is aged, and there are gaps and cracks in the connector housing, and the lens is damaged.
Maintenance Plan: Replace the lens and connector housing. (The matching layer needs to be dismantled for lens inspection)
2D Probe Repair | |
Service Brand | GE,,Siemens,Hitachi Aloka,Toshiba,Biosound Biosound,Sumsang Medison |
Service Type | Linear,Convex,Phased,Sector,Endocavity |
Repair Range | Membrane/lens replacement,Strain relief replacement,Electronic connector repair,Crystal/Array replacement,Plastic housing repair,Connecting cable repair |
Common ultrasound Probe Damage(Specialty 3D/4D Volume probes)
Common ultrasound probe damage | Solutions |
Lens cap damage | Lens cap replacement |
Fluid and oil leaks | Lens cap replacement, oil reservoir repair and replacement |
Cable cuts | Cable patches, possible cable replacement |
Inoperative steering | Motor repair |
Connector housing electrical damage | Minor electrical repairs, pin module replacement |
Weak or dead elements, dropouts in an image | Array ball replacement, oil reservoir repair and replacement |
Warnings and cautions of ultrasonic probe
★The ultrasonic probe is a valuable device. It must be careful in the process of use. Avoid dropping, impact, or abrasion to transducers.
★When installing or removing the probe, first switch off the power and then operate it carefully.
★Avoid rapid and extreme temperature changes, as well as lengthy exposure to direct sunlight or a strong ultraviolet light source.
★Do not use sharp objects to penetrate the acoustic lens.Once the acoustic lens is damaged, the coupling gel is easy to enter the interior of the probe and damage the piezoelectric element.
★Do not soak transducer in any liquid above the recommended level as stated in the user manual for your system, please operate according to the manufacturer's instructions, otherwise it will lead to circuit failure or even burn out.
★Do not disinfect at high temperature, because the probe is equipped with piezoelectric ceramics, high temperature will weaken the effect.
★Before use, carefully check whether the housing and cable are damaged, so as to prevent the probe from high voltage injury.
★After the probe is used, the residual coupling gel on the probe must be wiped clean to prevent rats or other animals from gnawing the lens.
Picture
FAQ
Q: Is there any guarantee for the goods?
A: Fully-tested and safe packing before shipping, less than 3% warranty return claims of previous orders.
Q: Will you provide warranty?
A: Items are sold with NO WARRANTY, unless it is stated otherwise in the body of the proforma invoice/purchase order. Mostly 90 days for new original, 30/60 days for used.
Q: If faults occurred after warranty date, can I contact you?
A: Sure, feel free to contact even years later. We'll look into the faults and try to find out some solutions/suggestions for you reference.
Q: How about the payment terms?
A: All orders are 100% prepaid before delivery. We accept wire transferring / Western Union from bank, and cash. (US dollars, Euro, or CNY)
Q: How about delivery?
A: We ship worldwide. DHL/EMS/FedEx Express will be arranged within 1-5 working days after payment confirmed unless otherwise specified. We Seller are responsible for export Customs clearance in our end, and buyers for import Customs clearance in their end.