Guangzhou Rongtao Medical Tech LTD.

To be the top preferred ultrasound service company worldwide!

Manufacturer from China
Verified Supplier
5 Years
Home / Products / Ultrasonic Board /

IO Board 5433408-120/5433408-121 GE LOGIQ E9 for Ultrasound System Repair/Sell

Contact Now
Guangzhou Rongtao Medical Tech LTD.
Visit Website
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:Aurora Zhu
Contact Now

IO Board 5433408-120/5433408-121 GE LOGIQ E9 for Ultrasound System Repair/Sell

Ask Latest Price
Video Channel
Brand Name :GE
Model Number :5433408-12
MOQ :1
Price :Negotiable
Payment Terms :T/T, Western Union
Delivery Time :2-4 work days
Packaging Details :Neutral Package
System :GE LOGIQ E9
Category :Medical ultrasonography
Description :Ultrasound IO Board
Service :Exchange/Repair
Warranty :60 days
Time Require :2-4 days
Application :Ultrasound machine
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

GE LOGIQ E9 Ultrasound IO Board

1.Part number: 5433408-120/5433408-121
2.Pre-owned original one ,in excellent condition
3.We provide 60 days warranty

Various GE/Siemens/Toshiba/Hitachi/ Biosound/Medison ultrasonic boards are within our repair/ maintenance range.

IO Board 5433408-120/5433408-121 GE LOGIQ E9 for Ultrasound System Repair/Sell

(GE IO Board 5433408-120)

IO Board 5433408-120/5433408-121 GE LOGIQ E9 for Ultrasound System Repair/Sell

(GE IO Board 5433408-121)

Other ultrasound parts related to GE that we can offer:

Brand System Description Part Number
GE Logiq P5 APS Power Supply 5140505/5166108/5329667
GE Logiq P5 CPU mainboard 5168431
GE Logiq P5 SYSCONPM 5177848-3
GE Logiq P6 CPU Mainboard
GE Logiq P6 PST Power Supply 5245004/5244555
GE Logiq P6 SYSCONML 5252326-3
GE Logiq S7/Logiq S8 CPS Power supply 6626600 R02/5413249-3
GE Logiq S7 BF128 transmitting board 5392446
GE Logiq S7 GFS board 5371196
GE Logiq S8 BF192 Beamformer 5357234-2
GE Logiq S8 GFS board 5371196-2/5455247
GE Logiq E9/vivid E9 GTX GA200726
GE Logiq E9 MRX Board 5393908/5393912
GE Logiq E9/vivid E9 GFI2 5161631
GE Logiq E9 BEP Power Supply 5393800-3/5166790-2
GE Voluson E6/Voluson E8 RSR KTI301394-2/KTI196357
GE Voluson E6/Voluson E8 RST KTI301148
GE Voluson E6/E8/E10 RSX KTZ303054 /KTI303054
GE Voluson E6/E8/E10 RFM201 FE mainboard KTZ303916
GE Voluson E6/E8/E10 RFM221 FE mainboard KTZ303915
GE Voluson E6/Voluson E8 RFI/ RFI21b Board KTI300614/KTI302197-6
GE Voluson S6/S8/P8 BF64 5396937-2
GE Voluson S6/S8/P8 BF128 5338209-2
GE Voluson S6/S8/P8 CPS Power supply 5393431
GE Voluson S6/S8/P8 RFS board 5364098-2/5364098-3
GE Voluson S6/S10/P8 BF192 board 5357234

Knowledge Point

GE LOGIQ E9 IO Board

1. Basic information
The IO Board in the GE LOGIQ E9 ultrasound diagnostic instrument is a key component inside the device. It is responsible for processing signal transmission and communication between the device and external devices (such as probes, displays, keyboards, etc.).

2. Functions and roles
Signal transmission: The IO Board acts as a bridge between the device and external devices to ensure accurate and fast transmission of information such as ultrasound signals, image data, and control commands.
Device communication: It may also be responsible for communication with other internal boards (such as processing boards, power boards, etc.) to ensure the coordinated operation of the entire ultrasound diagnostic instrument system.
Performance guarantee: The performance of the IO Board directly affects the image quality, response speed, and overall stability of the ultrasound diagnostic instrument.

3. Possible faults and solutions
Since it is impossible to directly give specific fault phenomena and solutions for the IO Board with a specific spare part number, based on the general maintenance experience of ultrasound diagnostic instruments, the following are some possible fault phenomena and general solutions:

No image display or abnormal image:
Check whether the connection between the IO Board and the display or probe is firm and whether the connection cable is damaged.
Try to replug the connection cable to see if it can be restored to normal.
If the problem persists, you may need to replace the IO Board or related components.
The device cannot recognize the probe:
Try replacing the probe to rule out problems with the probe itself.
If the problem persists, the probe interface on the IO Board may be faulty, and you may need to consider replacing the IO Board.

We provide professional ultrasonic plate repair services.10+years of professional maintenance service team.

If you need any product, please feel free to contact us.

Various Ultrasound Systems that we served

GE Ultrasound System
LOGIQ P5, LOGIQ P6, LOGIQ S7, LOGIQ S8, VOLUSON 730, VOLUSON S8, VOLUSON P8, VOLUSON S6, VOLUSON S20, VOLUSON P8, VOLUSON E10, VIVID E9, LOGIQ BOOK, LOGIQ 5, LOGIQ 7, LOGIQ 9, LOGIQ E9, LOGIQ F6, LOGIQ F8, VIVID I, VIVID Q, VOLUSON I, VOLUSON E, VIVID S5, VIVID 3, VIVID 7...

Hitachi-Aloka Ultrasound System
F31, F37, SSD-3500, SSD-3500, SSD-4000, SSD-5000, ALPHA 5, ALPHA 6, ALPHA 7, ALPHA 10, PROSOUND F75, HI VISION AVIUS, HI VISION PREIRUS, EUB-5500, EUB-6500, EUB-7500, EUB-8500, Arietta 60, Arietta 70, Ascendus...

Siemens Ultrasound System
S2000,S3000,SC2000,X300,P500,OXana,Juniper,Omini...

Inquiry Cart 0