Add to Cart
GE LOGIQ P9 MCB Board
1.P/N: 7494666
2.Pre-owned original one ,in excellent condition
3.We provide 60 days warranty
Various GE/Siemens/Toshiba/Hitachi/ Biosound/Medison Ultrasonic Boards(Parts) are within our repair/ maintenance range.
Knowledge Point
About GE Logiq P9 MCB Board
1. Function and location of MCB Board
Function: MCB Board is one of the core control boards of GE Logiq P9 ultrasound diagnostic instrument. It integrates multiple processing chips and interfaces, and is responsible for processing data from the probe, controlling various operations of the device, and outputting images to the display screen.
Location: MCB Board is usually located inside the main chassis of the device, and you need to remove the back cover to see it. The specific location may vary depending on the device model and configuration, but it is generally located at the back or bottom of the chassis.
2. Failure and maintenance of MCB Board
Failure manifestation: When the MCB Board fails, it may cause problems such as the device failing to start, no signal on the display, reduced image quality, and inability to function normally.
Repair method:
Diagnosis: First, you need to use professional diagnostic tools to detect the device fault to determine whether it is an MCB Board fault.
Replacement: If it is confirmed that the MCB Board is faulty, you need to replace a new control board. During the replacement process, you need to disconnect all cables and interfaces connected to the MCB Board and follow the device's maintenance manual.
Debugging: After replacing the new MCB Board, you need to debug and test the device to ensure that all functions are restored to normal.
3. Maintenance and care of MCB Board
Regular cleaning: Keep the inside and outside of the equipment clean, clean dust and dirt regularly to prevent damage to MCB Board and other components.
Avoid moisture: The equipment should be placed in a dry and ventilated environment to avoid moisture and high temperature from damaging MCB Board and other components.
Standard operation: When using the equipment, follow the specifications of the operating manual to avoid damage to MCB Board and other components caused by improper operation.
We provide professional ultrasonic plate repair services.10+years of professional maintenance service team.
If you need any product, please feel free to contact us.
Various Ultrasound Systems that we served
GE Ultrasound System |
LOGIQ P5, LOGIQ P6, LOGIQ S7, LOGIQ S8, VOLUSON 730, VOLUSON S8, VOLUSON P8, VOLUSON S6, VOLUSON S20, VOLUSON P8, VOLUSON E10, VIVID E9, LOGIQ BOOK, LOGIQ 5, LOGIQ 7, LOGIQ 9, LOGIQ E9, LOGIQ F6, LOGIQ F8, VIVID I, VIVID Q, VOLUSON I, VOLUSON E, VIVID S5, VIVID 3, VIVID 7... |
Hitachi-Aloka Ultrasound System |
F31, F37, SSD-3500, SSD-3500, SSD-4000, SSD-5000, ALPHA 5, ALPHA 6, ALPHA 7, ALPHA 10, PROSOUND F75, HI VISION AVIUS, HI VISION PREIRUS, EUB-5500, EUB-6500, EUB-7500, EUB-8500, Arietta 60, Arietta 70, Ascendus... |
Siemens Ultrasound System |
S2000,S3000,SC2000,X300,P500,OXana,Juniper,Omini... |