GE VIVID I Probe Interface Board
1.P/N: RPM12a-KTI300740-2
2.Pre-owned original one ,in excellent condition
3.We provide 60 days warranty
Various GE/Siemens/Toshiba/Hitachi/ Biosound/Medison Ultrasonic Boards(Parts) are within our repair/ maintenance range.
Other related GE Ultrasonic Parts we can provide:
Brand | System | Description |
GE | VIVID I/VIVID Q | ETX-PM PN:R2424348 R2423402 |
GE | vivid i | PC TO PFPC Boarf (P/N:2404907/5148771) |
GE | vivid i | DS power supply P/N:2416397-2 |
GE | vivid i | battery |
GE | vivid i | Display |
GE | vivid i/logiq e/voluson i | DFP 2394588 |
GE | vivid i/logiq e/voluson i | TR32 2354258-6 |
GE | vivid i/vivid e/vivid q/Vivid S6 | DC Power 5439596/5396104/R2403248-4/2408403-2/2408403-4 |
GE | vivid i | Probe Interface Board 2379846 |
Knowledge Point
About GE VIVID I Probe Interface Board
1. The role of the probe interface board
In the ultrasonic diagnostic instrument, the probe interface board is a key component, which is responsible for connecting the probe to the main part of the ultrasonic diagnostic instrument. Specifically, the functions of the probe interface board include:
Signal transmission: convert the ultrasonic signal received by the probe into an electrical signal and transmit it to the back end of the ultrasonic diagnostic instrument for processing.
Power supply: provide the necessary power for the probe to ensure the normal operation of the probe.
Communication and control: realize the communication and control between the ultrasonic diagnostic instrument and the probe to ensure the coordinated work between the two.
2. Probe interface board in GE VIVID I
In the GE VIVID I portable color Doppler ultrasonic diagnostic instrument, the probe interface board is an important bridge connecting the probe and the host. It is located at the front end of the device and is directly connected to the probe to ensure stable signal transmission and accurate control of the probe.
3. Possible faults and repairs
Since the probe interface board is one of the vulnerable parts in the ultrasonic diagnostic instrument, various faults may occur during use, such as unstable signal transmission, unrecognizable probe, power failure, etc. For these faults, the following maintenance measures can be taken:
Troubleshooting: First, determine the possible cause of the fault through the fault phenomenon, such as checking whether the probe interface is loose, whether the interface board is damaged, etc.
Replacement of accessories: If it is determined that the probe interface board is faulty, a new probe interface board needs to be replaced. During the replacement process, it is necessary to pay attention to the model and compatibility of the interface board to ensure that the new accessories can work properly.
Professional maintenance: If an individual cannot complete the maintenance work, it is recommended to contact a professional medical equipment maintenance organization or manufacturer for maintenance. They have professional maintenance skills and tools and can solve the problem quickly and accurately.
We provide professional ultrasonic plate repair services.10+years of professional maintenance service team.
If you need any product, please feel free to contact us.
Various Ultrasound Systems that we served
GE Ultrasound System |
LOGIQ P5, LOGIQ P6, LOGIQ S7, LOGIQ S8, VOLUSON 730, VOLUSON S8, VOLUSON P8, VOLUSON S6, VOLUSON S20, VOLUSON P8, VOLUSON E10, VIVID E9, LOGIQ BOOK, LOGIQ 5, LOGIQ 7, LOGIQ 9, LOGIQ E9, LOGIQ F6, LOGIQ F8, VIVID I, VIVID Q, VOLUSON I, VOLUSON E, VIVID S5, VIVID 3, VIVID 7... |
Hitachi-Aloka Ultrasound System |
F31, F37, SSD-3500, SSD-3500, SSD-4000, SSD-5000, ALPHA 5, ALPHA 6, ALPHA 7, ALPHA 10, PROSOUND F75, HI VISION AVIUS, HI VISION PREIRUS, EUB-5500, EUB-6500, EUB-7500, EUB-8500, Arietta 60, Arietta 70, Ascendus... |
Siemens Ultrasound System |
S2000,S3000,SC2000,X300,P500,OXana,Juniper,Omini... |